brooks@dbtower.cn    +8613666651334
Cont

Ada sebarang Soalan?

+8613666651334

Feb 16, 2022

monopole menara

monopole menara


 This specification document covers the projection principles for antenna mounted monopole towers to be used in GSM base station installation projects




Apabila terdapat percanggahan antara pelbagai spesifikasi standard atau data reka bentuk kejuruteraan, spesifikasi standard yang paling ketat hendaklah digunakan sebagai asas selepas kelulusan.


If revisions to the relevant standards are to be published, it is the contractor's responsibility to comply with the new standards and update production to those standards after approval has been obtained


Sistem metrik akan digunakan dalam pengukuran.





 3. Design principles


Melainkan jika diminta sebaliknya oleh pelanggan, menara akan direka bentuk mengikut ketinggian berikut.




 Unless otherwise requested by the customer, the tower will be designed according to the following heights.




Tiang tunggal boleh menjadi gabungan gelincir poligon atau pembuatan bebibir


Semua antena monopole hendaklah mempunyai aksesori untuk pemasangan antena, pengekalan kabel, tangga ke bahagian atas struktur serta pagar dan penyangkut keselamatan, pembumian, sistem konduktor kilat dan sistem lampu amaran pesawat.


Kontraktor hendaklah mereka bentuk pengiraan, lukisan garisan, lukisan fabrikasi dan pemasangan, lukisan fabrikasi dan bil bahan sebelum penghantaran.


Ia mesti direka untuk memudahkan operasi dan penyelenggaraan.


Elemen struktur dan penyambung akan didimensi mengikut keluaran terkini Garis Panduan Reka Bentuk Menara Penghantaran Keluli - ASCE yang dikeluarkan oleh American Society of Civil Engineers (ASCE).


Sebuah tangga akan dibina di atas monopole untuk penyelenggaraan dan pengendali memanjat menara. Jarak langkah adalah maksimum 30 cm. Pagar keselamatan dan alat penahan jatuh hendaklah disediakan untuk dipasang pada tangga akses.


Reka bentuk menara membolehkan pemasangan lampu amaran pesawat dan penangkap tembaga pada titik tertinggi, dengan panjang minimum 1.2 meter. Lampu amaran pesawat harus mudah diakses.


Kontraktor bertanggungjawab untuk mendapatkan keputusan daripada reka bentuk menara, ujian penerimaan dan jaminan kualiti untuk menunjukkan pematuhan kepada semua syarat yang dinyatakan dalam spesifikasi ini.


Kontraktor tidak boleh menggunakan monopole yang direka bentuk untuk sebarang tujuan lain tanpa kebenaran Pelanggan terlebih dahulu.


Setiap monopole hendaklah direka bentuk untuk berada dalam keratan rentas mendatar dodecagonal yang optimum-(memandangkan goyang dan getaran harus dikekalkan pada tahap minimum) dan-menyokong sendiri, dikira daripada tegangan-mampatan sistem daya.


Hayat monopole hendaklah sekurang-kurangnya 30 tahun.






 




 5. Platform


 Monopoles are available with or without top platform upon request and/or approval by Oman Mobile.

· The diameter of the top platform should be 3.0 m, and for monopole antennas without a top platform, a small shallow circular area should be provided for access to the antenna.

· Platforms should be fitted with non-slip floors, properly bolted to a suitable load bearing structure. Additionally, the platform floor must not allow tools and objects to fall.

· The top platform should be provided with footrests (h=15cm) and guard rails (made of two electric currents) with a height of not less than 110cm according to the current regulations.

· Work platforms should be accessed through hatches with opening and closing systems.


Hatch harus boleh terus terbuka jika perlu.


Semua sambungan bawah tanah ke sistem pembumian hendaklah menggunakan kaedah Cadweld.


 


7. Unsur keluli


Jika elemen penyambung bebibir, bilangan lampiran dan kesipian lampiran disimpan serendah mungkin.

· Dimensioning of elements and connecting elements will be in accordance with the latest issue of Steel Transmission Tower Design Guidelines - ASCE published by the American Society of Civil Engineers - ASCE.

· The necessary holes for grounding must be designed.


· Monopolar connection and fixation: The monopolar base plate is fixed to the concrete base with anchor bolts and is properly grouted

· If required, the Contractor shall conduct his own on-site survey and shall be responsible for obtaining all dimensions and levels required to properly manufacture the steelworks.

· It is the contractor's responsibility to make each piece to the correct form and size.


· The Contractor shall notify the Engineer of the date of commencement of fabrication, shall keep the Engineer informed of the fabrication schedule, and shall allow the Engineer or his representative full access to his factory at all reasonable times to be at any stage of his fabrication. It must be clearly understood by the Contractor that any material and workmanship that does not conform to this specification, whether at his workplace, on site or at the installation location, shall be rejected and replaced to the full satisfaction of the Engineer.


8. Andaian Beban Unipolar


Untuk reka bentuk monopole, beban berikut mesti dipertimbangkan: Pemuatan Antena:

· N degree 6 mobile antennas, each weighing 15 Kg and measuring 2.58 x 0.3 x 0.15 m.


· N degree 2 solid parabolic antenna with an average weight of 25 Kg and a diameter of 0,6 m.


Antena parabola pepejal N darjah 2 dengan berat purata 45 Kg dan diameter 1.2 m.


beban lain

Beban statik pada peralatan tambahan seperti penyuap, sambungan penyuap, struktur antena dan peralatan pemasangan lain.


Kelajuan angin:


· Design wind speed is 160 Km/h (45 m/s).


· The operating wind speed (at which maximum twist and tilt should be ±0.5 degrees) should be 120 Km/h (34 m/s).


10. Tangga dan Kaki Kabel


tangga kabel menegak


Tangga kabel menegak boleh menjadi kurungan luar pada tiang monopole berhampiran dengan tangga atau digunakan untuk menggantung kabel dalam

Cangkuk J-dalaman di dalam monopole.




11.


Tangga Kemasukan dan Sistem Perlindungan Jatuh Monopol hendaklah dilengkapi dengan tangga celup bergalvani panas dan sistem keselamatan yang diluluskan. Sistem keselamatan harus termasuk penahan jatuh (tetikus) yang boleh bergerak bebas pada kabel keluli atau landasan berterusan sepenuhnya dan yang mengunci dirinya sekiranya terjatuh untuk melindungi individu daripada terjatuh. Tangga hendaklah sekurang-kurangnya 400mm lebar. Jarak anak tangga (ketebalan minimum 16 mm) hendaklah maksimum 250 mm dan ia sepatutnya dapat menahan beban tertumpu 1 kN (gM=1.5). Sepatutnya tiada halangan pada kaki selepas menaiki tangga.


 12. Fasteners


Bolt, Nat dan Pencuci


Bolt lampiran, nat dan mesin basuh hendaklah memenuhi mana-mana piawaian berikut (atau yang setara):


Hantar pertanyaan